CVE-2026-9718: Schneider Electric PowerLogic P7 Denial-of-Service Vulnerability (CWE-617)
CVE-2026-9718 is a denial-of-service vulnerability affecting Schneider Electric PowerLogic P7 devices. An authenticated user with network access can send a specially crafted request that causes an assertion failure in the device firmware, crashing the service and disrupting availability. The attacker must already have valid credentials to exploit this—it is not remotely exploitable by anonymous users. Impact is limited to availability; confidentiality and integrity remain unaffected.
Source data · NVD / CISA · public domain
- CVSS
- 3.1 · 6.5 MEDIUM · CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
- Weaknesses (CWE)
- CWE-617
- Affected products
- 2 configuration(s)
- Published / Modified
- 2026-06-25 / 2026-07-01
NVD description (verbatim)
CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service.
1 reference(s) · View on NVD →
SEC.co analysis · AI-assisted, reviewed against source
Technical summary
This vulnerability is classified as CWE-617 (Reachable Assertion), a condition where an assertion statement in code can be triggered by attacker-controlled input, leading to program termination. The PowerLogic P7 firmware contains an assertion that can be reached by an authenticated attacker submitting a malformed or unexpected request over the network. When triggered, the assertion fails, causing the service to crash. The CVSS 3.1 score of 6.5 (MEDIUM) reflects a network-accessible service requiring valid authentication, with high impact to availability but no compromise of confidentiality or integrity.
Business impact
Disruption of the PowerLogic P7 energy monitoring and management platform will impair visibility into power consumption and grid metrics critical to facility operations, potentially delaying incident response, load management decisions, and compliance reporting. Organizations relying on continuous monitoring for demand response or power quality management face operational blind spots during outages. Recovery requires manual intervention and system restart, extending downtime.
Affected systems
Schneider Electric PowerLogic P7 firmware and the PowerLogic P7 device itself are affected. This is industrial control equipment commonly deployed in commercial buildings, data centers, and utility environments for power monitoring. Verify the specific firmware version installed in your environment against the Schneider Electric security advisory for detailed version constraints.
Exploitability
Exploitation requires valid authentication credentials and network access to the PowerLogic P7 service. The attack is straightforward once authenticated—the attacker needs only to send a specially crafted request—but the authentication barrier significantly reduces exposure. Insider threats and compromised accounts pose the primary risk. The vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog, indicating no evidence of active exploitation in the wild as of the publication date.
Remediation
Apply the security patch released by Schneider Electric. Verify the patched firmware version by consulting the official Schneider Electric security advisory. Additionally, enforce network segmentation to restrict PowerLogic P7 access to authorized management networks only, and enforce strong authentication controls to limit credential compromise risk.
Patch guidance
Consult the Schneider Electric security advisory for PowerLogic P7 to identify the specific patched firmware version applicable to your hardware model and current firmware level. Test the patch in a non-production environment before deployment to validate compatibility and avoid disruption. Schneider Electric typically provides firmware update tools and detailed upgrade procedures in their product documentation.
Detection guidance
Monitor PowerLogic P7 service logs for unexpected assertions or crashes correlated with malformed requests. Network-based detection should focus on identifying anomalous request patterns to the device's management interface. Endpoint detection tools monitoring the device itself may flag abnormal termination events. Baseline normal traffic patterns to improve signal-to-noise ratio when hunting for exploit attempts.
Why prioritize this
Although the CVSS score is MEDIUM (6.5), prioritization depends on your operational reliance on PowerLogic P7 for critical power management and the likelihood of insider threats or account compromise in your environment. Organizations with high availability requirements, limited network segmentation, or weak access controls should prioritize patching. The authentication requirement substantially reduces enterprise risk compared to unauthenticated remote vulnerabilities.
Risk score, explained
The CVSS 3.1 score of 6.5 reflects: (1) Network-accessible service (AV:N), (2) Low attack complexity once authenticated (AC:L), (3) Requirement for valid user credentials (PR:L), (4) No user interaction needed (UI:N), (5) Impact limited to availability (A:H), with no confidentiality or integrity loss (C:N, I:N). The authentication prerequisite prevents the score from reaching HIGH or CRITICAL severity, as it eliminates anonymous remote exploitation.
Frequently asked questions
Can an unauthenticated attacker exploit this vulnerability?
No. CVE-2026-9718 requires valid authentication credentials and authenticated network access to the PowerLogic P7 service. This substantially limits exposure to authorized users, insiders, or attackers who have compromised legitimate accounts.
What happens when the vulnerability is triggered?
The vulnerable assertion in the firmware fails, causing the PowerLogic P7 service to crash. This disrupts power monitoring capabilities until the service is manually restarted. System data and configurations are not lost, but real-time visibility into power metrics is interrupted.
Is this vulnerability exploited in the wild?
As of the publication date, CVE-2026-9718 is not listed in the CISA Known Exploited Vulnerabilities catalog. There is no public evidence of active exploitation in the wild, though that does not guarantee future exploitation risk.
How should I prioritize patching if I cannot immediately deploy updates?
Focus on network segmentation and access control: restrict PowerLogic P7 management access to a hardened management network, enforce multi-factor authentication on admin accounts, and monitor for suspicious access patterns. These interim controls reduce the likelihood of successful exploitation while you plan and execute patching.
This analysis is based on publicly available information as of the vulnerability publication and modification dates. Patch version numbers and specific firmware constraints must be verified against the official Schneider Electric security advisory. SEC.co does not provide exploit code or weaponized proof-of-concept demonstrations. Organizations should conduct their own risk assessment based on their specific deployment, network architecture, and threat model. Testing any patches in non-production environments is mandatory before production deployment. Source: NVD (public-domain), retrieved 2026-08-03. Analysis generated by SEC.co (claude-haiku-4-5).
Related vulnerabilities
- CVE-2026-46220MEDIUMLinux AMDGPU Kernel Panic DoS Vulnerability
- CVE-2026-46287MEDIUMLinux txgbe Driver RTNL Locking Defect
- CVE-2026-46542MEDIUMNimiq Ed25519 Denial-of-Service Vulnerability (Version 1.4.0 Patch)
- CVE-2026-46543MEDIUMNimiq Remote Node Crash Vulnerability
- CVE-2026-47145MEDIUMEmberZNet DoS Vulnerability via Color Control Messages
- CVE-2026-47146MEDIUMEmberZNet Color Control Denial of Service (CVSS 6.5)
- CVE-2026-52718MEDIUMGStreamer AV1 Parser Denial of Service Vulnerability
- CVE-2026-52961MEDIUMLinux Kernel Ceph Filesystem Race Condition Causing Kernel Panic