HIGH 7.4

CVE-2026-48294: Adobe Acrobat Chrome Extension UXSS Session Data Disclosure

A vulnerability exists in Adobe Acrobat's PDF viewer extension for Chrome that allows attackers to steal session data from victims. The flaw is classified as a cross-site scripting (XSS) issue that can bypass same-origin protections, meaning malicious content on one website could access sensitive information from another site. An attacker would need to trick a user into visiting a malicious webpage or clicking a specially crafted link. The vulnerability affects Acrobat versions 26.5.2.2 and earlier.

Source data · NVD / CISA · public domain

CVSS
3.1 · 7.4 HIGH · CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N
Weaknesses (CWE)
CWE-79
Affected products
1 configuration(s)
Published / Modified
2026-06-17 / 2026-06-29

NVD description (verbatim)

Adobe Acrobat PDF Extension (Chrome) versions 26.5.2.2 and earlier are affected by a UXSS-class cross-origin data disclosure vulnerability. An attacker could exploit this vulnerability to gain access to data regarding the victim's session. Exploitation of this issue requires user interaction in that a victim must visit a maliciously crafted URL or interact with a compromised web page. Scope is changed.

1 reference(s) · View on NVD →

SEC.co analysis · AI-assisted, reviewed against source

Technical summary

CVE-2026-48294 is a universal XSS (UXSS) vulnerability in the Adobe Acrobat PDF Extension for Chrome that enables cross-origin data disclosure. The vulnerability stems from improper handling of same-origin policy enforcement, allowing script execution within privileged extension contexts to access data across security boundaries. The CVSS 3.1 vector (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N) reflects network exploitability with low complexity, user interaction requirement, scope change, and confidentiality impact. This is mapped to CWE-79 (improper neutralization of input during web page generation). The scope change parameter indicates the vulnerability can affect resources beyond the vulnerable component itself.

Business impact

Session hijacking via this vulnerability could expose user authentication tokens, browsing history, and sensitive document metadata accessed through the Acrobat extension. For organizations where users routinely open PDFs from external sources or email, the risk of data exfiltration is elevated. Attackers could craft phishing emails or malicious websites that exploit this flaw to harvest session credentials without triggering obvious security warnings, potentially compromising both personal and corporate data handling.

Affected systems

Adobe Acrobat PDF Extension for Chrome in versions 26.5.2.2 and earlier are affected. Users running these versions on any operating system supported by Chrome (Windows, macOS, Linux) face exploitation risk. The vulnerability does not affect standalone Adobe Acrobat Reader or other browsers' PDF handlers unless they use the same underlying vulnerable extension code.

Exploitability

Exploitation is practical but requires user interaction—a victim must be directed to a malicious URL or compromised webpage. The attack complexity is low, meaning a standard attacker with network access can craft the exploit without specialized resources or privileged system access. No authentication is required. The active exploitation likelihood is moderate; while the technique requires social engineering, UXSS vulnerabilities are well-understood in the security community and proof-of-concept development is straightforward.

Remediation

Users should update the Adobe Acrobat PDF Extension for Chrome to a version later than 26.5.2.2. Adobe typically delivers updates through the Chrome Web Store automatically; users can manually verify the extension version in Chrome's extension settings. Organizations should enforce extension update policies and consider disabling the extension if an immediate update is not feasible. Where feasible, use alternative PDF viewers or restrict PDF opening to trusted sources.

Patch guidance

Verify that the Adobe Acrobat PDF Extension for Chrome is updated to the latest available version beyond 26.5.2.2 by checking chrome://extensions in your browser and confirming the extension version number. If automatic updates are disabled, manually update by visiting the Chrome Web Store page for the extension or ensure auto-update is enabled in browser settings. Test the patched version with internal PDF workflows to ensure no compatibility issues. Document the patch date for compliance records.

Detection guidance

Monitor Chrome extension permissions and versions in your environment using endpoint management tools. Detect anomalous script execution within the Acrobat extension context using browser security monitoring or EDR solutions capable of browser process inspection. Hunt for suspicious cross-origin requests originating from PDF-viewing sessions. Review web proxy logs for attempts to access URLs hosting UXSS payloads. Educate users to avoid clicking untrusted PDF links and to verify sender authenticity before opening attachments.

Why prioritize this

This vulnerability merits urgent attention despite not being on the KEV catalog. The combination of high CVSS score (7.4), practical user-interaction-based exploitation, scope change enabling cross-origin attacks, and the prevalence of Chrome browser usage in enterprise environments creates significant organizational risk. Session data disclosure can cascade into lateral movement or credential theft. The low barrier to exploitation (no special tools required) means threat actors will likely develop functional exploits quickly.

Risk score, explained

The CVSS 7.4 HIGH rating reflects: (1) network-reachable attack surface with no privilege requirements; (2) low attack complexity allowing easy exploitation; (3) user interaction as a practical but single point of friction; (4) scope change indicating the vulnerability compromises security mechanisms beyond the vulnerable component; (5) high confidentiality impact through session and data disclosure. The score does not factor ransomware activity or active exploitation in the wild, which would further elevate real-world risk for organizations.

Frequently asked questions

Does this vulnerability affect Adobe Acrobat Reader installed as a standalone application?

No. CVE-2026-48294 specifically affects the Adobe Acrobat PDF Extension for Chrome. Standalone Adobe Acrobat Reader on Windows or macOS is not vulnerable. However, if users have the Chrome extension installed alongside Reader, the extension should be updated independently.

What if a user has disabled auto-updates on the Chrome Web Store?

Manual intervention is required. Users should open chrome://extensions, locate the Adobe Acrobat extension, and verify the current version. If it shows 26.5.2.2 or earlier, enable auto-update or manually reinstall the extension from the Chrome Web Store to force the latest patched version.

Can this vulnerability be exploited if a user simply views a PDF file locally without opening it in a browser?

Not directly. The vulnerability requires the Chrome extension context. If a user opens a PDF through Chrome (by downloading and opening it, or via chrome://, or by the extension handling PDF display), the risk exists. Opening PDFs in standalone applications or other browsers bypasses this specific vulnerability.

Is there a workaround if we cannot patch immediately?

Uninstalling or disabling the Adobe Acrobat PDF Extension in Chrome is the most reliable workaround. Users can then view PDFs using Chrome's built-in PDF viewer or Firefox's native handler. Alternatively, restrict users from visiting untrusted websites and enforce email gateway scanning to block malicious PDF links until patches are deployed.

This analysis is based on the published CVE record and Adobe's vulnerability disclosures as of June 2026. CVSS scores and severity assessments reflect the vendor's evaluation at publication time and may not reflect all real-world exploitation scenarios. Organizations should verify patch availability and compatibility with their specific Chrome and Acrobat versions before deployment. This document does not constitute security advice tailored to any specific organization; consult your security team for deployment decisions. Vulnerability intelligence is subject to change as new information emerges. Source: NVD (public-domain), retrieved 2026-07-26. Analysis generated by SEC.co (claude-haiku-4-5).