HIGH 8.8

CVE-2026-11523: Stack Buffer Overflow in Tenda W20E Web Management Interface

A stack-based buffer overflow vulnerability has been discovered in Tenda W20E firmware version 15.11.0.6. An authenticated attacker can manipulate the 'gotoUrl' parameter in the web management interface's portal authentication function to overflow a stack buffer, potentially gaining full control of the device. Public exploits for this vulnerability are available, elevating the risk of active exploitation.

Source data · NVD / CISA · public domain

CVSS
3.1 · 8.8 HIGH · CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weaknesses (CWE)
CWE-119, CWE-121
Affected products
0 configuration(s)
Published / Modified
2026-06-08 / 2026-06-17

NVD description (verbatim)

A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

7 reference(s) · View on NVD →

SEC.co analysis · AI-assisted, reviewed against source

Technical summary

CVE-2026-11523 is a stack-based buffer overflow (CWE-121) stemming from improper input validation (CWE-119) in the formPortalAuth function of the /goform/PortalAuth endpoint. The vulnerability resides in the Web Management Interface of Tenda W20E 15.11.0.6. By supplying an oversized or specially crafted 'gotoUrl' parameter, an authenticated user can overwrite stack memory, leading to arbitrary code execution with the privileges of the web server process. The network-accessible nature of the management interface and low attack complexity make this a practical remote threat.

Business impact

Successful exploitation allows an authenticated attacker to execute arbitrary code on affected Tenda routers, resulting in complete device compromise. Business-critical impacts include unauthorized access to network traffic, lateral movement into internal networks, DNS hijacking, malware distribution, and persistent backdoor installation. Organizations relying on Tenda W20E devices for network infrastructure or remote access are particularly vulnerable to data exfiltration, regulatory violations (HIPAA, PCI-DSS), and operational disruption.

Affected systems

Tenda W20E firmware version 15.11.0.6 is confirmed vulnerable. Organizations should audit their environment for this specific model and firmware version. Users are advised to check Tenda's official product documentation and security advisories to determine if other firmware versions or related Tenda product lines are affected, as vendors often patch multiple versions concurrently or reveal broader exposure during disclosure.

Exploitability

This vulnerability requires an authenticated user on the local network or with valid credentials to the web management interface—a meaningful but not insurmountable barrier in many environments. The attack is network-accessible, has low complexity, and public exploits are already available. The combination of authentication requirement (CVSS PR:L) and released proof-of-concept code significantly elevates real-world risk; attackers can now leverage compromised credentials, social engineering, or insider threats to trigger remote code execution without advanced reverse engineering.

Remediation

The primary remediation is immediate firmware patching. Tenda should release a patched firmware version addressing the input validation flaw in the gotoUrl parameter. Until patches are available, mitigations include restricting access to the web management interface via network segmentation, firewall rules limiting access to trusted IP ranges, changing default credentials, and monitoring for suspicious authentication or management interface activity. Consider temporarily disabling remote management features if operationally feasible.

Patch guidance

Check Tenda's official support website and security advisories for the latest firmware release. Verify that any patched firmware version explicitly addresses CVE-2026-11523 before deployment. Apply patches during a maintenance window with adequate testing in a non-production environment first. Document the baseline firmware version and post-patch version for compliance records. If Tenda has not yet released a patch, subscribe to their security notifications and implement compensating controls (network isolation, access restrictions) until an update becomes available.

Detection guidance

Monitor web server and access logs for POST requests to /goform/PortalAuth with abnormally large or malicious-looking 'gotoUrl' parameter values. Implement network intrusion detection rules to flag oversized or suspicious parameter payloads sent to this endpoint. Correlate authentication logs with crash reports or unexpected process behavior on the device. Memory-based threat detection or runtime application self-protection (RASP) on the router, if available, may catch buffer overflow attempts. Regular firmware integrity checks and unexpected binary modification alerts are also valuable.

Why prioritize this

This vulnerability rates as HIGH priority (CVSS 8.8) due to the combination of remote network accessibility, full confidentiality/integrity/authenticity impact, publicly available exploits, and the critical role routers play in network infrastructure. Although authentication is required, the barrier is relatively low—particularly in environments with weak credential hygiene. Immediate action is warranted to patch affected systems or implement strong compensating controls.

Risk score, explained

The CVSS 3.1 score of 8.8 reflects a HIGH severity assessment: Network-accessible attack vector (AV:N), low attack complexity (AC:L), low privilege requirement (PR:L for authenticated users), no user interaction needed (UI:N), unchanged scope (S:U), and high impact across confidentiality, integrity, and availability (C:H/I:H/A:H). The availability of public exploits further justifies treating this as a near-term threat rather than theoretical risk.

Frequently asked questions

Do I need to be on the local network to exploit this vulnerability?

No. CVE-2026-11523 is remotely exploitable over the network, though it requires valid authentication credentials to the Tenda W20E web management interface. If the management interface is exposed to the internet or accessible from untrusted networks, the threat surface expands significantly.

What firmware versions besides 15.11.0.6 are affected?

The public disclosure specifically identifies Tenda W20E 15.11.0.6 as vulnerable. You should consult Tenda's official security advisory to confirm whether other firmware versions (earlier, later, or on related product lines) are also affected, as vendors sometimes patch multiple versions or discover broader scope during incident response.

Can this vulnerability be exploited without any user action?

Yes. The vulnerability can be triggered remotely by an authenticated attacker without requiring any user interaction on the target device—for example, no clicking of links or approval of prompts. This increases the risk of automated or large-scale exploitation once an attacker has credentials.

What should I do if I cannot patch immediately?

Implement network segmentation to restrict access to the web management interface to trusted administrative IP addresses only. Disable remote management if it is not required. Enforce strong, unique credentials and multi-factor authentication where supported. Monitor access logs and authentication attempts closely for signs of compromise or brute-force attacks.

This analysis is provided for informational purposes and reflects publicly disclosed information as of June 2026. Security analysts should verify vendor advisories, patch availability, and applicability to their specific environment before taking action. SEC.co makes no warranty regarding the completeness, accuracy, or fitness for any particular purpose of this content. Organizations must conduct their own risk assessment and testing before applying patches or implementing compensating controls. Consult Tenda's official security advisories for definitive guidance on affected versions, patch release timelines, and product-specific remediation. Source: NVD (public-domain), retrieved 2026-07-15. Analysis generated by SEC.co (claude-haiku-4-5).