CVE-2025-2902: Hitachi Virtual Storage Platform Authorization Bypass in Maintenance Utility
Hitachi Virtual Storage Platform systems contain an authorization flaw in a maintenance utility that allows authenticated users to perform actions they should not be permitted to carry out. An attacker with valid credentials can exploit this weakness to make unauthorized changes to storage configurations or access sensitive data. The vulnerability requires an existing user account but no special privileges to trigger, making it a meaningful risk in environments where storage access is shared across teams or where former employees retain credentials.
Source data · NVD / CISA · public domain
- CVSS
- 3.1 · 8.3 HIGH · CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H
- Weaknesses (CWE)
- CWE-862
- Affected products
- 0 configuration(s)
- Published / Modified
- 2026-06-29 / 2026-06-29
NVD description (verbatim)
Improper Authorization Vulnerability of Maintenance Utility in Hitachi Virtual Storage Platform. This issue affects Hitachi Virtual Storage Platform E390, E590, E790, E990, E1090, E390H, E590H, E790H, E1090H: before DKCMAIN Ver. 93-07-26-xx/00, GUM Ver. 93-07-26/00; Hitachi Virtual Storage Platform 5100, 5500, 5100H, 5500H, 5200, 5600, 5200H, 5600H: before DKCMAIN Ver. 90-09-27-00/00, GUM Ver. 90-09-27/00; Hitachi Virtual Storage Platform G130, G150, G350, G370, G700, G900, F350, F370, F700, F900: before DKCMAIN Ver. 88-08-16-xx/00, GUM Ver. 88-08-20/00.
1 reference(s) · View on NVD →
SEC.co analysis · AI-assisted, reviewed against source
Technical summary
CVE-2025-2902 is an improper authorization vulnerability (CWE-862) in Hitachi Virtual Storage Platform maintenance utilities. The flaw allows authenticated users to bypass authorization checks, leading to unauthorized modification of storage settings and potential confidentiality breaches. The vulnerability exists in the DKCMAIN and GUM (Graphical User Interface for Management) components across multiple VSP hardware generations. The CVSS 3.1 score of 8.3 reflects a high-severity condition: network-adjacent attack surface, low complexity, and significant impact on integrity and availability, though some confidentiality exposure is also present.
Business impact
Unauthorized changes to storage configurations can disrupt service availability, corrupt data, or expose sensitive information stored on the VSP systems. In regulated industries (finance, healthcare, government), such breaches trigger compliance violations and notification obligations. Storage platforms are often central to business continuity; unauthorized access or modification creates data integrity concerns that may require costly forensic investigation and system restoration. Depending on what data resides on affected VSP systems, a single compromised user account could affect multiple applications and business units.
Affected systems
This vulnerability affects Hitachi Virtual Storage Platform E-series (E390, E590, E790, E990, E1090, and H variants), VSP 5000-series (5100, 5500, 5200, 5600, and H variants), and VSP G/F-series (G130, G150, G350, G370, G700, G900, F350, F370, F700, F900). Organizations running DKCMAIN or GUM versions older than the specified patched versions are exposed. The breadth of affected models means most enterprise Hitachi storage deployments warrant immediate assessment.
Exploitability
The vulnerability requires valid login credentials but no elevated privileges, making it exploitable by any authenticated user—including contractors, former employees with lingering access, or accounts created for service integration. No user interaction or special conditions are required once authenticated. The network-accessible nature of storage management interfaces increases the window of exposure. However, exploitation requires initial access to the VSP management interface, which is typically restricted to administrative networks in well-segmented environments.
Remediation
Apply vendor-supplied firmware updates to bring DKCMAIN and GUM components to the specified patched versions. For VSP E-series and H variants, update to DKCMAIN Ver. 93-07-26-xx/00 or later and GUM Ver. 93-07-26/00 or later. For VSP 5000-series, update to DKCMAIN Ver. 90-09-27-00/00 or later and GUM Ver. 90-09-27/00 or later. For VSP G/F-series, update to DKCMAIN Ver. 88-08-16-xx/00 or later and GUM Ver. 88-08-20/00 or later. Coordinate patching with your storage vendor to minimize downtime. Concurrently, audit user access and revoke credentials for unused accounts, especially former employees or temporary contractors.
Patch guidance
Hitachi typically releases storage firmware updates through their support portal and requires scheduling maintenance windows due to the critical nature of storage systems. Verify compatibility of target patch versions with your specific VSP model and existing configurations before deployment. Test patches in a non-production environment if possible. Given the high CVSS score and the sensitivity of storage systems, prioritize this update in your patch cycle. Check Hitachi's advisory for any interim guidance on disabling the maintenance utility or restricting access while patches are in flight.
Detection guidance
Monitor management interface logs for unusual authentication patterns, failed authorization attempts, or configuration changes by users lacking administrative roles. If your VSP sends syslog or audit events, look for maintenance utility invocations by non-administrator accounts or unexpected administrative actions attributed to standard user accounts. Network detection should flag any outbound connections from VSP management interfaces to unexpected destinations. Correlate VSP access logs with employee status records to identify stale credentials being used. If you have endpoint detection and response (EDR) agents on management hosts, monitor for suspicious access to VSP management APIs or utilities.
Why prioritize this
This vulnerability merits immediate attention due to its high CVSS score (8.3), the central role of storage systems in infrastructure, the low barrier to exploitation (any authenticated user), and the potential for data loss or integrity compromise. While not yet on the CISA KEV list, the risk of unauthorized storage reconfiguration or data access by insiders or low-privilege accounts justifies treating this as a critical priority. The broad range of affected VSP models increases the likelihood that your organization runs vulnerable hardware.
Risk score, explained
The CVSS 3.1 score of 8.3 (HIGH) reflects: (1) Network accessibility to the management interface (AV:N), (2) Low attack complexity—no special conditions required (AC:L), (3) Requirement for low-privilege authentication (PR:L), (4) No user interaction needed (UI:N), (5) Significant integrity impact from unauthorized configuration changes (I:H), (6) Potential availability impact if the utility is used to disable or degrade storage services (A:H), and (7) Some confidentiality risk if the utility allows reading configuration or metadata. The score appropriately captures that an authorized but unprivileged user can cause serious harm.
Frequently asked questions
Do I need privileged credentials to exploit this vulnerability?
No. The vulnerability can be exploited by any authenticated user, including those with standard or read-only roles. You do not need administrative privileges to trigger the authorization bypass in the maintenance utility.
What is the difference between DKCMAIN and GUM, and do I need to patch both?
DKCMAIN is the storage system firmware component, while GUM is the graphical management interface. Both contain the vulnerable authorization logic and must be updated to the patched versions specified for your VSP model to fully remediate the issue.
Is this vulnerability being actively exploited?
As of the publication date, this vulnerability is not listed on the CISA Known Exploited Vulnerabilities (KEV) catalog, suggesting no confirmed widespread exploitation. However, the low barrier to exploitation means it could be leveraged opportunistically by insiders or attackers with valid credentials.
How long does a typical VSP firmware update take?
Firmware updates for storage systems typically require a maintenance window of 30 minutes to several hours, depending on your configuration and whether non-disruptive update techniques are available. Coordinate with Hitachi support and your storage team to schedule the update with minimal business impact.
This analysis is based on the CVE record as published and Hitachi's vulnerability description. Patch version numbers and affected model information must be verified against Hitachi's official security advisory before deployment. Testing patches in a non-production environment is strongly recommended. SEC.co does not provide legal or compliance advice; organizations in regulated sectors should consult their compliance teams regarding remediation timelines and notification requirements. This page does not constitute a substitute for vendor-issued guidance or professional security consultation. Source: NVD (public-domain), retrieved 2026-08-07. Analysis generated by SEC.co (claude-haiku-4-5).
Weaknesses (CWE)
Related vulnerabilities
- CVE-2018-25391HIGHHaPe PKH 1.1 Authorization Bypass – Unauthorized Record Deletion Vulnerability
- CVE-2024-32949HIGHMissing Authorization in Prince Integrate Google Drive — HIGH Risk
- CVE-2025-26418HIGHAndroid CarDevicePolicyService Privilege Escalation (CVSS 7.8)
- CVE-2025-48617HIGHAndroid CarrierConfigLoader Privilege Escalation Vulnerability
- CVE-2025-48640HIGHAndroid Passkey Permission Bypass Privilege Escalation
- CVE-2025-53345HIGHThimPress Thim Core Missing Authorization Leads to Code Execution
- CVE-2025-69134HIGHUnauthenticated Content Deletion in OpenAI Chatbot for WordPress – Helper
- CVE-2025-69189HIGHEMV JobBank Missing Authorization Vulnerability